Follow Us :

Pharmaceutical Solutions through Blogs and Courses

Blog

By Dr. Pramod Kr. Pandey - May 3, 2025

Dr. Pramod Kr. Pandey is a distinguished Analytical Research Expert with over three decades of extensive experience in the pharmaceutical industry. He has contributed his expertise to both leading Indian and global pharmaceutical companies, consistently driving innovation and excellence in analytical research

Learn about HETP (Height equivalent to a theoretical plate). Explore its definition, calculation formula, influencing factors, applications, and real-world case studies to optimize column efficiency

HETP (Height Equivalent To A Theoretical Plate) In Chromatography Separation: Know Everything

HETP (Height Equivalent to a Theoretical Plate), also known simply as H, is one of the key parameters used to assess the efficiency of a column’s separation. HETP represents the height of the column required for the analyte to reach equilibrium between the stationary and mobile phases during separation. A lower HETP value indicates a more efficient column and better separation performance.

This article provides a comprehensive overview of HETP, covering its definition, the formula used for its calculation, and the factors that influence it. You will also explore its practical applications in chromatography, examine real-world case studies, and find answers to frequently asked questions to help you understand and optimise HETP in your analytical work.

You may Like:

HETP (Height equivalent to a theoretical plate)

HETP (Height equivalent to a theoretical plate) is the property of the column, which is defined as the height of the column required by the analyte to achieve equilibration between the stationary phase and the mobile phase. It is denoted by HETP or H.

HETP Calculation Formula

The following formula is used to calculate the HETP:

HETP (Height equivalent to a theoretical plate)
HETP Formula

When N will be 1, then HETP = L

Hence, HETP can be defined as “HETP is the length of the column which represents 1 (one) theoretical plate. It means lower the HETP and better the column.

Difference between HETP (Height equivalent to a theoretical plate and Column efficiency

HETPColumn efficiency
Lower the value of HETP better the columnThe higher the value of HETP better the column

Van-Deemter Equation (Relationship between HETP and flow rate)

Van-Deemter equation

Factors Affecting HETP

The following are the resolution controlling factors in HPLC:

  1. Column efficiency: HETP is inversely proportional to the column efficiency
  2. Column length: L is directly proportional to the column length
  3. Particle size: HETP is directly proportional to the particle size.
  4. Column temperature: HETP is inversely proportional to the column temperature
  5. Injection volume: HETP is directly proportional to the buffer concentration
  6. Sample concentration: HETP is directly proportional to the sample concentration
  7. Eddy diffusion: HETP is directly proportional to the Eddy diffusion.
  8. Longitudinal diffusion: HETP is directly proportional to Longitudinal diffusion.
  9. Equilibration mass transfer: HETP is directly proportional to the Equilibration mass transfer
  10. Flow rate: HETP is directly proportional to the flow rate

Relationship between HETP (H) and h (Reduced plate height)

Reduced plate height (h)

Applications of HETP

HETP helps to assess the efficiency of a chromatographic separation process. The following are the various applications of HETP:

  • HPLC and GC
  • Distillation Processes
  • Process Engineering
  • Food and Beverage Industry
  • Pharmaceutical Industry
  • Petroleum and Petrochemical Industries
  • Chemical Analysis

HPLC and GC

  • Performance Evaluation: HETP is used to assess the efficiency of chromatographic columns. A lower HETP indicates better separation performance and higher resolution in separating compounds.
  • Optimization of Separation: By monitoring HETP, one can optimize the flow rate, column dimensions, and other parameters to improve the quality of separation in both analytical and preparative chromatography.
  • Column Design and Selection: It helps in selecting or designing the most suitable columns for specific separations by considering the required resolution and efficiency.
  • Very helpful in selecting the column during chromatographic method development
  • The lower the value of HETP better is the method/column
  • The lower the value of HETP sharper the peak

Distillation Processes

  • Designing Distillation Columns: In distillation, HETP is used to design and optimize distillation columns. The number of theoretical plates in a column correlates with its separation efficiency, and a lower HETP means fewer plates are needed for the same separation efficiency.
  • Optimization of Operating Conditions: By adjusting factors like reflux ratio, feed composition, and column temperature, operators can reduce HETP, improving energy efficiency and product purity in industrial distillation processes.

Process Engineering

  • Scale-Up: HETP is used when scaling up laboratory separations to industrial scales. It helps predict how separation efficiency changes when moving from small laboratory columns to large industrial equipment.

Food and Beverage Industry

  • Purification of Food Ingredients: In the production of flavorings, additives, or essential oils, HETP helps optimize separation processes for extracting desired compounds with minimal loss and maximum purity.

Pharmaceutical Industry

  • Purification of Drugs and Active Pharmaceutical Ingredients (APIs): HETP is important in optimizing the separation of active ingredients from impurities or solvents during the production of pharmaceuticals. It helps ensure high purity and consistency of the final product.

Petroleum and Petrochemical Industries

  • Refining and Fractionation: In the refining of crude oil or gas, HETP is used to optimize the distillation processes involved in separating various hydrocarbon fractions such as gasoline, diesel, and kerosene.

Chemical Analysis

  • Analytical Chemistry: In chemical analysis, HETP provides valuable insights into column efficiency and can be used for the validation of chromatographic methods, particularly in the analysis of complex mixtures.

HETP Case Study: Optimisation of HPLC Column Efficiency

Background:

A pharmaceutical laboratory is analysing a mixture containing paracetamol, caffeine, and aspirin in a commercial tablet formulation using HPLC. The aim is to optimise the separation to achieve sharp peaks and baseline resolution within the shortest run time.

Objective:

Evaluate and compare the efficiency of different HPLC columns using HETP as a metric and identify the best conditions for optimal separation.

HPLC Condition Setup:

  • Mobile Phase: Methanol:Water (60:40, v/v)
  • Flow Rate: 1.0 mL/min
  • Detector: UV at 254 nm
  • Sample: Tablet extract containing paracetamol, caffeine, and aspirin
  • Columns Tested:
    1. Column A: C18, 150 mm × 4.6 mm, 5 µm
    2. Column B: C18, 100 mm × 4.6 mm, 3 µm
    3. Column C: C8, 150 mm × 4.6 mm, 5 µm

Experiment and Observations:

Each sample was injected, and the following data were collected:

ColumnCompoundRetention Time (RT)
(minute)
Peak Width (Wb)
(minute)
HETP (mm)
AParacetamol3.20.420.21
ACaffeine5.10.480.28
BParacetamol2.70.330.13
BCaffeine4.20.380.19
CParacetamol3.40.490.27

Note: HEPT was calculated using formula 1

Summary and Conclusion

  • Column B (3 µm particles, shorter length) showed the lowest HETP values, indicating higher efficiency and better separation in a shorter time.
  • While Column A offered decent efficiency, its longer length and larger particles resulted in higher HETP.
  • Column C (C8) had poorer retention and resolution, especially for aspirin, due to its less hydrophobic nature.

Conclusion

HETP is widely used in chromatographic separation in the pharmaceuticalindustrys. Hopefull,y this article has cleared all your doubts related to HETP and you can now use it effectively during HPLC separation method development. Write your opinion/ question related to this article in the comment section and I will answer it on a priority basis.

You may also want to check out other articles on my blog, such as:

FAQS

What is HETP in HPLC?

HETP (height equivalent to a theoretical plate) is the property of the column, which is defined as the height of the column required by the analyte to achieve equilibration between the stationary phase and the mobile phase. It is denoted by HETP or H.

How do you calculate the HETP of a chromatography column?

HETP = L/N; where L is the length of the column (in millimeter/centimeter/meter) and N is the theoretical plate or column efficiency

What is the significance of HETP?

Lower the HETP and better the column. HETP = L/N; where L is the length of the column (in millimetres/centimetres/meter) and N is the theoretical plate or column efficiency.

What is the relation between HETP and the theoretical plate?

HETP is inversely proportional to theoretical plate


What is the difference between HETP and column efficiency or theoretical plate?

The difference between HETP and column efficiency or theoretical plate is that HETP (Height Equivalent to a Theoretical Plate) is a measure of column performance, while column efficiency or theoretical plate is a measure of the number of theoretical plates in the column. HETP and flow rate have an inverse relationship – as flow rate increases, HETP decreases. HETP and reduced height have a direct relationship – as reduced height increases, HETP also increases. HETP is used to evaluate the performance of packed columns in chromatography and distillation processes.

What is the relationship between HETP and flow rate?

H=A+B/v+Cv

Where:

  • A : Eddy diffusion
  • B: Longitudinal diffusion
  • C: Equilibration mass transfer &
  • v: Flow rate

References:

  • Analytical Chemistry, Gary D. Christian
  • HETP

Abbreviations:

  • HETP: Height equivalent to theoretical plate
  • N: column efficiency
  • h: Reduced height.
  • HPLC: High performance liquid chromatography

About Dr Pramod Kumar Pandey
Dr. Pramod Kr. Pandey

Dr. Pramod Kr. Pandey is a distinguished Analytical Research Expert with over three decades of extensive experience in the pharmaceutical industry. He has contributed his expertise to both leading Indian and global pharmaceutical companies, consistently driving innovation and excellence in analytical research

Subscribe to Stay Informed with the Latest Industry Insights!

Leave a Reply

Your email address will not be published. Required fields are marked *

error: Content is protected !!
×